What is a universal washroom?
• Universal washrooms are enclosed washrooms providing a barrier-free toilet and sink and turning space to. accommodate a wheeled mobility device. A power door operator must be provided at the entrance door.
What is a barrier-free path of travel?
A barrier-free path of travel must extend from a barrier-free entrance into and throughout all normally occupied floor areas (some exemptions apply), and is permitted to consist of: a ramp; a passenger elevating device; or. an elevator.
What is the minimum width of a single swinging egress door assuming it doesn’t have to be barrier-free )?
3.3(1) Doorway Width. Every doorway that is located in a barrier-free path of travel must have a clear width of not less than 860mm (33 7/8’1 when the door is in the open position and therefore it is important that this dimension be measured correctly.
What are the minimum dimensions of a door to a public washroom required by OBC?
The Ontario Building Code | Doorways and Doors (b) 810 mm where the door is served by a corridor or space less than 1 060 mm wide. (b) be mounted not less than 900 mm and not more than 1 100 mm above the finished floor.
How many washrooms are required Ontario?
The Ontario Building Code | Washrooms Required to be Barrier-Free
Item | Column 1 Number of Storeys in Building | Column 2 Minimum Number of Universal Washrooms per Building |
---|---|---|
1. | 1 to 3 | 1 |
2. | 4 to 6 | 2 |
3. | Over 6 | 3, plus 1 for each additional increment of 3 storeys in excess of 6 storeys |
How do barrier free showers work?
Unlike a traditional shower tray, a barrier-free shower or walk-in shower is completely level with the floor. With a walk-in shower a tray is not necessary because the floor is sloped towards the drain, so all the water will drain efficiently.
What is the minimum width of a corridor in a barrier-free path of travel in Millimetres?
1,100 mm wide
Explanation: The Alberta Building Code 2014 3.8. 3.2. (1)(b) requires exterior barrier-free paths of travel to be no less than 1,100 mm wide.
How wide does a wheelchair ramp need to be?
36 inches
The ramp must have a 1:12 slope ratio. This means that there must be a one-inch rise in the ramp for every corresponding 12 inches of the ramp. Minimum width of 36 inches, although this can be higher in certain states. The ramp cannot be longer the 30 feet without a rest platform, in order to prevent fatigue.
Do exit doors have to swing out?
Side-hinged exit doors must be used to connect rooms to exit routes. These doors must swing out in the direction of exit travel if the room is to be occupied by more than 50 people or if the room is a high-hazard area.
Do doors have to swing in the direction of egress?
A door in a means of egress should be side-hinged or pivoted-swinging. Doors must swing in the direction of exit travel when: 1. Serving a room or area with an occupant load of 50 or more.
How wide is a door in Ontario?
According to the specifications, the standard door size Canada is found to be 6 ft 8 in by 3 ft 96 in. With newer exterior doors, homeowners can also think of having the dimensions measuring at 30 and 32 inches in width. There are also doors that are measured at 7 ft and 8ft in height and 24-inch to 42-inch in width.
What is the latest version of Ontario building code?
May 2, 2019. The ministry amended Ontario’s Building Code (O. Reg 332/12) to further harmonize Ontario’s Building Code with the 2015 National Codes.